Results 1 - 20 de 128
Filter
2.
Rev. eletrônica enferm ; 24: 1-11, 18 jan. 2022.
Article in English, Portuguese | LILACS, BDENF | ID: biblio-1411227

ABSTRACT

Objetivo: avaliar a presença de biofilme nas películas de smartphones de profissionais da saúde, investigar o padrão de uso e de descontaminação dos smartphones no ambiente de assistência à saúde em um hospital de médio porte. Métodos: estudo analítico e transversal, realizado com profissionais de saúde que possuíam smartphone. Foram realizadas entrevistas estruturadas e a presença de biofilme nas películas de vidro dos smartphones foi avaliada pela microscopia eletrônica de varredura. Resultados: todas as amostras de películas foram positivas para presença de biofilme, mesmo após descontaminação com álcool a 70%. Dos participantes, 96,4% utilizavam smartphone no ambiente de trabalho, a maioria utilizava o aparelho para fins pessoais e descontaminavam com álcool a 70% com frequência irregular. Conclusões: o smartphone pode servir como fômite, visto que biofilmes foram detectados na superfície das películas. Esses achados apontam para a necessidade de políticas de controle de infecção relacionadas ao uso dos smartphones.


Objective: to evaluate the presence of biofilm on the protective glass films of smartphones of health professionals, to investigate the pattern of use and decontamination of smartphones in the health care environment of a medium-sized hospital. Methods: analytical and cross-sectional study, carried out with health professionals with smartphones. Structured interviews were carried out and the presence of biofilm on the protective glass films of smartphones was evaluated by scanning electron microscopy. Results: all film samples were positive for the presence of biofilm, even after decontamination with alcohol 70%. 96.4% of the participants used a smartphone in the work environment, most used the device for personal purposes and decontaminated it with alcohol 70% with irregular frequency. Conclusion(s): the smartphones can serve as a fomite, considering that biofilms were detected on the surface of the films. These findings point to the need for infection control policies related to the use of smartphones.


Subject(s)
Equipment Contamination/prevention & control , Infection Control , Health Personnel
3.
Rev. latinoam. enferm. (Online) ; 30: e3684, 2022. tab, graf
Article in English | LILACS, BDENF | ID: biblio-1409620

ABSTRACT

Abstract Objective: to analyze the cleaning process of gastroscopes, colonoscopes and duodenoscopes in eight in-hospital health services. Method: a cross-sectional study conducted with 22 endoscopes (eight gastroscopes, eight colonoscopes and six duodenoscopes), and microbiological analysis of 60 samples of air/water channels (all endoscopes) and elevator (duodenoscopes), in addition to protein testing. Descriptive statistics with calculation of frequencies and central tendency measures was used in data analysis. Results: the processing of 22 endoscopes was monitored with microbiological analysis for 60 channels. In the pre-cleaning procedure, in 82.3% (14/17) of the devices, gauze was used in cleaning the insertion tube. Incomplete immersion of the endoscope in detergent solution occurred in 72.3% (17/22) of the cases, and in 63.6% (14/22) there was no standardization of filling-in of the channels. Friction of the biopsy channel was not performed in 13.6% (3/22) of the devices. In the microbiological analysis, 25% (7/32) of the samples from the stored endoscopes were positive for microbial growth (from 2x101 to 9.5x104 CFU/mL), while after processing, contamination was 32% (9/28). Protein residues in the elevator channel were detected in 33% of duodenoscopes. Conclusion: the results indicate important gaps in the stages of pre-cleaning and cleaning of endoscopes that, associated with presence of protein residues and growth of microorganisms of epidemiological importance, indicate limitations in safety of the processing procedures, which can compromise the disinfection processes and, consequently, their safe use among patients subjected to such tests.


Resumo Objetivo: analisar o processo de limpeza de gastroscópios, colonoscópios e duodenoscópios em oito serviços de saúde intra-hospitalar. Método: estudo transversal com 22 endoscópios, sendo oito gastroscópios, oito colonoscópios e seis duodenoscópios, e análise microbiológica de 60 amostras dos canais de ar/água (todos os endoscópios) e elevador (duodenoscópios), além de teste de proteína. Na análise dos dados, utilizou-se estatística descritiva, com cálculo de frequências e medidas de tendência central. Resultados: o processamento de 22 endoscópios foi acompanhado com análise microbiológica de 60 canais. Na pré-limpeza, em 82,3% (14/17) dos equipamentos, foi utilizada gaze na limpeza do tubo de inserção. A imersão incompleta do endoscópio em solução detergente ocorreu em 72,3% (17/22) dos casos, e em 63,6% (14/22) não havia padronização do preenchimento dos canais. A fricção do canal de biópsia não foi realizada em 13,6% (3/22) dos equipamentos. Na análise microbiológica, 25% (7/32) das amostras dos endoscópios armazenados foram positivas para crescimento microbiano (2x101 a 9,5x104 UFC/mL), enquanto após o processamento, a contaminação foi de 32% (9/28). Resíduos de proteína no canal do elevador foram detectados em 33% dos duodenoscópios. Conclusão: os resultados apontam lacunas importantes nas etapas de pré-limpeza e limpeza dos endoscópios que, associadas à presença de resíduos de proteína e ao crescimento de microrganismo de importância epidemiológica, sinalizam limitações na segurança do processamento, que podem comprometer os processos de desinfecção e consequentemente seu uso seguro entre pacientes submetidos a tais exames.


Resumen Objetivo: analizar el proceso de limpieza de gastroscopios, colonoscopios y duodenoscopios en ocho servicios de salud intrahospitalarios. Método: estudio transversal con 22 endoscopios, de los cuales ocho eran gastroscopios, ocho colonoscopios y seis duodenoscopios, y análisis microbiológico de 60 muestras de los canales de aire/agua (todos los endoscopios) y elevador (duodenoscopios), además de prueba de proteínas. En el análisis de los datos se utilizó estadística descriptiva, con cálculo de frecuencias y medidas de tendencia central. Resultados: el procesamiento de los 22 endoscopios fue monitoreado con el análisis microbiológico de 60 canales. En la prelimpieza, en el 82,3% (14/17) de los equipos se utilizó gasa para limpiar el tubo de inserción. En el 72,3% (17/22) de los casos la inmersión del endoscopio en solución detergente fue incompleta y en el 63,6% (14/22) no hubo estandarización del llenado de los canales. La fricción del canal de biopsia no se realizó en el 13,6% (3/22) de los equipos. En el análisis microbiológico, el 25% (7/32) de las muestras endoscópicas almacenadas dio positivo para crecimiento microbiano (2x101 a 9,5x104 UFC/ml), mientras que después del procesamiento, la contaminación fue del 32% (9/28). Se detectaron residuos de proteína en el canal elevador en el 33% de los duodenoscopios. Conclusión: los resultados indican que hay importantes lagunas en las etapas de prelimpieza y limpieza de los endoscopios que, junto con la presencia de residuos de proteínas y del crecimiento de microorganismos de importancia epidemiológica, indican limitaciones en la seguridad del procesamiento, que pueden comprometer los procesos de desinfección y, por ende, el uso seguro en los pacientes que se someten a esos procedimientos.


Subject(s)
Humans , Disinfection , Cross Infection , Equipment Contamination/prevention & control , Cross-Sectional Studies , Endoscopes/microbiology , Detergents
4.
Rev. cir. (Impr.) ; 73(2): 132-140, abr. 2021. tab
Article in Spanish | LILACS | ID: biblio-1388806

ABSTRACT

Resumen Objetivo: En este estudio se comparan los desenlaces clínicos de cuatro técnicas de apendicectomía laparoscópica utilizadas en una institución colombiana para el manejo de la apendicitis aguda tras la adopción de políticas de reúso y reprocesamiento de dispositivos médicos para la Región de las Américas (2014). Materiales y Método: Mediante el análisis de varianza de una vía (ANOVA) y la prueba de Kruskal Wallis, se compararon las tasas de infección de sitio operatorio (ISO), reoperación no planeada, readmisión y mortalidad (en los primeros 30 días del postoperatorio) de las siguientes técnicas: Técnica 1: Ligadura del muñón apendicular con endonudo y disección del mesenterio apendicular con electrocoagulación bipolar convencional; Técnica 2: Clipaje del muñón con endoclip de polímero y disección del mesenterio con electrocoagulación bipolar convencional; Técnica 3: Clipaje del muñón con endoclip de polímero y disección del mesenterio con electrocoagulación monopolar; Técnica 4: Clipaje del muñón y disección roma y ligadura del mesenterio con endoclip de polímero. Resultados: Se incluyeron 551 pacientes. No se encontraron diferencias en los ANOVAs en cuanto a las características demográficas de los pacientes por cada técnica. Los desenlaces globales fueron: ISO (5,44%), reoperación no planeada (3,08%), readmisión (15,97%) y mortalidad (0,18%). Se encontraron diferencias significativas (p < 0,05) en estos desenlaces explicados por mayores tasas de ISO y reoperación con la Técnica-1. Conclusiones: Los desenlaces globales de la apendicectomía laparoscópica tras la adopción de políticas de reúso de dispositivos médicos se encuentran dentro de los aceptados globalmente cuando se utilizan las Técnicas 2-3-4 en poblaciones equivalentes de pacientes con apendicitis aguda. En este contexto, nuestros resultados invitan a utilizar con precaución la Técnica-1.


Aim: The present study sought to compare the clinical outcomes between four operative techniques for laparoscopic appendectomy in a Colombian institution, following the adoption of reuse and reprocessing policies for medical devices in the Region of Americas (2014). Materials and Methods: One-way analysis of variance (ANOVA) and Kruskal Wallis tests were used to compare the rates of Surgical Site Infection (SSI), unplanned reoperation, readmission and mortality (confined to 30 days after surgery) of these operative techniques: Technique 1: Ligature of appendiceal stump with endo stitch plus mesenteric dissection with conventional bipolar electrocoagulation; Technique 2: Clipping of stump with polymer endoclip plus mesenteric dissection with conventional bipolar electrocoagulation; Technique 3: Clipping of stump with polymer endoclip plus mesenteric dissection with monopolar electrocoagulation; Technique 4: Clipping of stump plus mesenteric dissection with polymer endoclip. Results: A total of 551 patients were included. No differences were found in the demographic characteristics of the patients between techniques during ANOVAs. The global outcomes were SSI (5.44%), unplanned reoperation (3.08%), readmission (15.97%) and mortality (0.18%). Significant differences were found (p < 0.05) in these outcomes explained by higher rates of SSI and unplanned reoperation with Technique 1. Conclusions: The overall outcomes of laparoscopic appendectomy, after the adoption of policies for the reuse and reprocessing of medical devices, are similar to those accepted globally when using operative techniques 2-3-4 in equivalent populations of patients with acute appendicitis. In this context, our results invite to use with caution technique-1.


Subject(s)
Humans , Male , Female , Appendectomy/methods , Laparoscopy/methods , Equipment Reuse/standards , Appendectomy/adverse effects , Equipment Contamination/prevention & control , Treatment Outcome , Laparoscopy/adverse effects
5.
Rev. latinoam. enferm. (Online) ; 29: e3475, 2021. graf
Article in English | LILACS, BDENF | ID: biblio-1341518

ABSTRACT

Objective: to compare the efficacy of 80% (w/v) alcohol, rubbed for 30 and 60 seconds, in the manual processing of stainless-steel wash bowls, after cleaning with running water and neutral detergent. Method: experimental study conducted in a hospital in the state of São Paulo, Brazil, on 50 bowls randomly divided into two groups of 25 bowls each for interventions of 30 and 60 seconds of rubbing with 80% (w/v) alcohol. Results: based on the microbiological analyses collected, before and after the interventions for both groups, partial efficacy of the disinfectant was observed even when extending rubbing time. In both groups, there was a higher prevalence of survival of Pseudomonas aeruginosa, with 14 strains that were resistant to carbapenems, being, specifically, 11 to imipenem and three to meropenem. Conclusion: stainless-steel bed wash bowls decontaminated for reuse by 80% (w/v) alcohol, after cleaning with running water and neutral detergent, showed to be reservoirs of hospital pathogens. The use of bed wash bowls for patients with intact skin would not have worrying consequences, but considering those with non-intact skin and the contamination of professionals' hands, the results in this study justify the search for other decontamination methods or the adoption of disposable bed baths.


Objetivo: comparar a eficácia do álcool 80% (p/v), friccionado por 30 e 60 segundos, no processamento manual de bacias de banho em aço inoxidável, após limpeza com água corrente e detergente neutro. Método: estudo experimental realizado em hospital do estado de São Paulo, Brasil, com 50 bacias randomicamente distribuídas em dois grupos de 25, para as intervenções de 30 e 60 segundos de fricção com álcool 80% (p/v). Resultados: das análises microbiológicas coletadas, antes e após as intervenções para os dois grupos, verificou-se eficácia parcial do desinfetante, mesmo ampliando o tempo de fricção. Em ambos os grupos, observou-se maior prevalência de sobrevida de Pseudomonas aeruginosa, 14 cepas resistentes a carbapenens, especificamente, 11 ao imipenen e três ao meropenen. Conclusão: bacias de banho no leito em aço inoxidável, descontaminadas para reuso com álcool 80% (p/v), após limpeza com água corrente e detergente neutro, apresentam-se como reservatórios de patógenos hospitalares. O uso das bacias de banho no leito para pacientes com pele íntegra não teria consequências preocupantes, mas para aqueles com pele não íntegra e pensando na contaminação das mãos dos profissionais, os resultados dessa pesquisa justificam a busca de outros métodos de descontaminação ou a adoção de banho de leito descartável.


Objetivo: comparar la eficacia del alcohol al 80% (p/v), frotado durante 30 y 60 segundos, en el proceso de descontaminación manual de palanganas de baño de acero inoxidable, después de lavarlas con agua corriente y detergente neutro. Método: estudio experimental realizado en un hospital del estado de São Paulo, Brasil, con 50 palanganas divididas aleatoriamente en dos grupos de 25, para intervenciones de 30 y 60 segundos de frotamiento con alcohol al 80% (p/v). Resultados: los análisis microbiológicos recolectados, antes y después de las intervenciones para ambos grupos, demostraron efectividad parcial del desinfectante, incluso cuando se extendió el tiempo de fricción. En ambos grupos, se observó una mayor prevalencia de supervivencia de Pseudomonas aeruginosa, 14 cepas resistentes a carbapenemas, específicamente 11 a imipenem y tres a meropenem. Conclusión: las palanganas de baño de cama de acero inoxidable, descontaminadas para su reutilización con alcohol al 80% (p/v), después del lavado con agua corriente y detergente neutro, actúan como reservorios de patógenos hospitalarios. El uso de las palanganas de baño de cama no tendría consecuencias preocupantes para pacientes con la piel íntegra, pero para aquellos cuya piel no conserva su integridad y pensando en la contaminación de las manos de los profesionales, los resultados de esta investigación justifican la búsqueda de otros métodos de descontaminación o la adopción del baño de cama desechable.


Subject(s)
Humans , Stainless Steel , Brazil , Decontamination , Equipment Contamination/prevention & control , Ethanol
6.
Acta odontol. latinoam ; 33(1): 45-49, June 2020. graf
Article in English | LILACS | ID: biblio-1130732

ABSTRACT

ABSTRACT The guttapercha cones used in endodontic treatment are produced in aseptic conditions and their composition includes zinc oxide, which is responsible for antibacterial activity. However, there is the possibility of microbial contamination by manipulation, aerosol or during storage. Although several chemical agents have been tested for their decontamination, there is no consensus on the best disinfection protocol to be used. The aim of this study was to evaluate the decontamination of guttapercha cones contaminated with the bacteria Enterococcus faecalis, by using chlorhexidine digluconate (CHX) and sodium hypochlorite (NaClO) at different concentrations for short exposure times. For this purpose, guttapercha cones (size 40) were selected at random from a sealed box and immersed for 1 min in a microbial suspension. Then they were immersed in specific Petri dishes for different groups containing: CHX 2%, NaClO 1% or NaClO 2.5% for 30 s or 1 min, and subsequently placed in tubes containing BHI broth. After incubating the tubes for 48 h, it was observed that 1% and 2.5% NaClO and 2% CHX were effective for decontaminating the cones at those exposure time intervals. Microbial growth was detected in one of the replicates of the group with CHX applied for 30 s. To prevent the possibility of failures at this stage, the exposure time of guttapercha cones to the decontaminating agent should not be reduced.


RESUMO Os cones de gutapercha utilizados no tratamento endodôntico são produzidos em condições assépticas e possuem óxido de zinco em sua composição, responsável pela atividade antibac te riana. No entanto, existe a possibilidade de contaminação microbiana por manipulação, aerossol ou seu armazenamento. Embora vários agentes químicos já tenham sido testados para sua descontaminação, não há consenso sobre o melhor proto colo de desinfecção a ser usado. Nosso objetivo foi avaliar a descontaminação de cones de gutapercha contaminados com a bactéria Enterococcus faecalis, utilizando digluconato de clorexidina (CHX) e hipoclorito de sódio (NaClO) em diferentes concentrações e tempos de exposição curtos. Para esse fim, 40 cones de gutapercha foram selecionados aleatoriamente, de uma caixa selada e imersos por 1 min em uma suspensão microbiana. Em seguida, foram imersos em placas de Petri específicas para diferentes grupos contendo: CHX 2%, NaClO 1% ou 2,5%, nos tempos de exposição de 30s e 1min e subseqüentemente imersos em tubos contendo caldo BHI. Após incubação dos tubos por 48 h, observouse que NaClO 1% e 2,5% e CHX 2% foram eficazes para a descontaminação dos cones nesses intervalos de tempo de exposição. Em uma das réplicas do grupo com CHX aplicado por 30s foi detectado crescimento microbiano. O tempo de exposição dos cones de gutapercha ao agente de desconta minação não deve ser reduzido para evitar a possibilidade de falhas nesse estágio.


Subject(s)
Humans , Root Canal Irrigants/pharmacology , Sodium Hypochlorite/pharmacology , Chlorhexidine/analogs & derivatives , Sterilization/methods , Decontamination/methods , Enterococcus faecalis/drug effects , Dental Disinfectants/pharmacology , Gutta-Percha , Root Canal Filling Materials , Root Canal Irrigants/administration & dosage , Sodium Hypochlorite/administration & dosage , Chlorhexidine/pharmacology , Equipment Contamination/prevention & control , Enterococcus faecalis/isolation & purification , Dental Disinfectants/administration & dosage , Anti-Infective Agents, Local
9.
Int. j. odontostomatol. (Print) ; 14(3): 310-315, 2020.
Article in Spanish | LILACS | ID: biblio-1114897

ABSTRACT

El SARS-CoV-2 es un tipo de coronavirus con un alto grado de contagio entre pacientes y personal de salud, por lo que ha provocado la emergencia sanitaria más grande de los últimos años. Los equipos de protección personal (EPP) tienen como indicación un único uso, sin embargo, la escasez de estos ha llevado a buscar métodos para descontaminarlos y reutilizarlos, asegurando su disponibilidad. La evidencia presenta múltiples procedimientos para descontaminar mascarillas con filtro respirador tipo N95 (MFR N95), pero el método ideal debe inactivar al patógeno, asegurar la integridad del filtro respirador, el ajuste de la mascarilla y la salud del personal que la utilizará. La descontaminación con peróxido de hidrógeno vaporizado, irradiación germicida ultravioleta e incubación con calor húmedo se presentan como los métodos más eficaces contra distintos patógenos. Ante la creciente demanda de EPP y MFR N95, se sugiere realizar más estudios clínicos, que evalúen la eficacia de los métodos de descontaminación específicamente contra SARS-CoV-2 y se generen protocolos que permitan reutilizar con total seguridad este vital elemento para el personal de salud.


SARS-CoV-2 is a type of coronavirus with a high risk of contagion among patients and health care workers (HCW), being the cause of the largest health emergency in recent years. Personal Protective Equipment (PPE) are indicated for a single use. However, shortage has led to research new methods to decontaminate and reuse them, ensuring its availability. Evidence presents multiple procedures to decontaminate Filtering Facepiece Respirators type N95 (FFR), despite this, the ideal treatment should inactivate the pathogen, to ensure filter integrity, mask adjustments and the safety of who use this elements. Decontamination methods as vaporized hydrogen peroxide, ultraviolet germicidal irradiation and moist heat are the most effective procedures against different pathogens. Facing the rising demand of PPE and FFR, it's suggested to conduct researches to evaluate decontamination methods efficacy, and specifically against SARS-CoV-2, to generate protocols in ways to let to HCW reuse FFR N95 totally safe.


Subject(s)
Humans , Pneumonia, Viral/prevention & control , Respiratory Protective Devices , Decontamination/methods , Coronavirus Infections/prevention & control , Pandemics/prevention & control , Disinfection , Equipment Contamination/prevention & control , Equipment Reuse , Infectious Disease Transmission, Patient-to-Professional/prevention & control , Filtration , Betacoronavirus , Masks
10.
Rev. Col. Bras. Cir ; 47: e20202549, 2020. tab, graf
Article in Portuguese | LILACS | ID: biblio-1136557

ABSTRACT

RESUMO Atualmente médicos e profissionais da saúde encontram-se frente a uma pandemia desafiadora causada por uma nova cepa denominada 2019 Novel Coronavírus (COVID-19). A infecção humana pelo COVID-19 ainda não tem o espectro clínico completamente descrito, bem como não se sabe com precisão o padrão de letalidade, mortalidade, infectividade e transmissibilidade. Não há vacina ou medicamento específico disponível. O tratamento é de suporte e inespecífico. No Brasil, assim como no restante do mundo o número de casos de COVID-19 tem crescido de maneira alarmante levando a um aumento do número de internações assim como da mortalidade pela doença. Atualmente os estados com maior número de casos são, respectivamente, São Paulo, Rio de Janeiro, Distrito Federal e Ceará. O objetivo deste trabalho é oferecer alternativas a fim de orientar cirurgiões quanto ao manejo cirúrgico das vias aéreas em pacientes com suspeita e/ou confirmação para infecção pelo COVID-19.


ABSTRACT Currently doctors and health professionals are facing a challenging pandemic caused by a new strain called 2019 Novel Coronavirus (COVID-19). Human infection with COVID-19 does not yet have the clinical spectrum fully described, and the pattern of lethality, mortality, infectivity and transmissibility is not known with precision. There is no specific vaccine or medication available. Treatment is supportive and nonspecific. In Brazil, as in the rest of the world, the number of COVID-19 cases has grown alarmingly, leading to an increase in the number of hospitalizations as well as in mortality from the disease. Currently, the states with the highest number of cases are, respectively, São Paulo, Rio de Janeiro, Distrito Federal and Ceará. The objective of this work is to offer alternatives in order to guide surgeons regarding the surgical management of the airways in patients with suspicion and / or confirmation for COVID-19 infection.


Subject(s)
Humans , Pneumonia, Viral/surgery , Coronavirus Infections/surgery , Airway Management/methods , Betacoronavirus , Pneumonia, Viral/prevention & control , Postoperative Care/standards , Risk Management/standards , Tracheostomy/standards , Equipment Contamination/prevention & control , Occupational Exposure/prevention & control , Coronavirus Infections/prevention & control , Airway Management/standards , Pandemics/prevention & control , Surgeons/standards , SARS-CoV-2 , COVID-19 , Laryngeal Muscles/surgery
11.
Rev. Salusvita (Online) ; 39(1): 43-51, 2020.
Article in Portuguese | LILACS | ID: biblio-1119413

ABSTRACT

Um dos meios eficazes para evitar a contaminação cruzada dentro dos consultórios odontológicos é a correta esterilização dos materiais pelo uso de autoclaves. O monitoramento desses equipamentos constitui estratégia importante no controle dos serviços prestados pela vigilância sanitária. O objetivo do presente trabalho foi comprovar a eficiência de autoclaves de consultórios odontológicos privados de cinco cidades diferentes do interior de Mato Grosso do Sul. O monitoramento das autoclaves foi realizado utilizando-se indicadores biológicos Clean-Test®. Das 37 autoclaves analisadas, apenas 2 apresentaram falhas do processo de esterilização.


One of the most effective ways to avoid cross-contamination inside dental offices is the correct sterilization of materials. The monitoring of this equipment is an important strategy in controlling the services provided by health surveillance. The objective of the present work was to prove the efficiency of autoclaves of autoclaves in private dental offices in five different cities in the interior of Mato Grosso of Sul. The monitoring of the autoclaves was performed using CleanTest® biological indicators. Of the 37 autoclaves analyzed, only 2 showed flaws in the sterilization process.


Subject(s)
Sterilization/instrumentation , Dental Instruments , Biological Monitoring , Equipment Contamination/prevention & control , Cross-Sectional Studies , Dental Offices
13.
Rev. chil. ortop. traumatol ; 60(3): 86-90, dic. 2019. ilus
Article in Spanish | LILACS | ID: biblio-1146625

ABSTRACT

OBJETIVO: Encuestar a cirujanos de rodilla en Chile, sobre su conducta en contaminaciones accidentales del injerto, en reconstrucciones de ligamento cruzado anterior (LCA). MÉTODOS: Se realizó una encuesta anónima en relación a la incidencia, tratamiento y resultados clínicos de los injertos de LCA contaminados, a todos los médicos pertenecientes al área de traumatología y ortopedia asistentes al congreso Ateneo de rodilla 2015. RESULTADOS: Se encuestaron 54 médicos, 33 (61%) especialistas en cirugía de rodilla y 21 (39%) médicos en formación. De los cirujanos de rodilla, 15 (45%) reportaron al menos un caso de contaminación, de los cuales 12 (80%) informaron un único evento, 3 (20%) indicaron la eventualidad en 2, 3 y 5 ocasiones respectivamente, para un total de 22 injertos contaminados. De los cirujanos que reportaron injertos contaminados, 11 (73%) realizan 50 o más reconstrucciones al año. La decisión tomada en los casos de contaminación fue en 13 oportunidades (59%), lavar el injerto y utilizarlo de acuerdo al plan inicial; en 6 casos (27%), utilizar aloinjerto; en 2 ocasiones (9%), utilizar autoinjerto alternativo; y en 1 oportunidad (5%); triplicar el semitendinoso. Ninguno de los casos de contaminación reportó infecciones. CONCLUSIONES: En casos de una contaminación accidental, la mayoría de los cirujanos encuestados prefieren optar por la descontaminación del injerto y su utilización en la reconstrucción de acuerdo al plan inicial; para lo cual la clorhexidina y antibióticos sería la solución a usar de preferencia. NIVEL DE EVIDENCIA: Nivel V, opinión de experto.


OBJECTIVE: To survey knee surgeons who perform anterior cruciate ligament (ACL) reconstruction in Chile, about the management when ACL graft contamination occurs. METHODS: An anonymous survey was conducted to all physicians belonging to the area of traumatology and orthopedics who attended the 2015 annual Chilean Knee Society meeting. The survey questioned the incidence, treatment, and outcomes of ACL graft contaminations. RESULTS: Fifty-four physicians were surveyed, of which 33 (61%) where knee surgeons and 21 (39%) physicians in training. Of the 33 knee surgeons, 15 (45%) reported at least one contamination during their career. Of those 15, 12 (80%) had one event, and three surgeons (20%) informed having 2, 3, and 5 episodes respectively, for a total of 22 reported contaminated grafts. Of the surgeons who reported a contaminated graft, 11 (73%) performed 50 or more ACL reconstructions annually. In 13 opportunities (59%) the management for a contaminated graft was cleansing the graft and proceeding as planned. In 6 cases (27%) an allograft was used, in 2 occasions (9%) a different graft was harvested, and in 1 opportunity (5%) a semitendinosus graft triplication was performed. No infections in any of the contaminated grafts were reported. CONCLUSIONS: In case of accidental graft contamination during an ACL reconstruction, knee surgeons most often preferred disinfecting the graft and using it as the initial plan. LEVEL OF EVIDENCE: Level V, expert opinion.


Subject(s)
Humans , Accidents , Equipment Contamination/statistics & numerical data , Transplants/microbiology , Anterior Cruciate Ligament Reconstruction/methods , Orthopedic Surgeons/psychology , Chlorhexidine/administration & dosage , Sterilization/methods , Decontamination , Equipment Contamination/prevention & control , Surveys and Questionnaires , Disinfectants/administration & dosage , Allografts/microbiology , Autografts/microbiology , Anti-Bacterial Agents
14.
Int. j. odontostomatol. (Print) ; 13(3): 357-362, set. 2019. tab
Article in English | LILACS | ID: biblio-1012436

ABSTRACT

ABSTRACT: The contamination of the dental units' waterlines is a reality, which can develop individual and collective disorders. The aim of this study was to evaluate the prevalence and resistance profile of bacteria on the internal surfaces of waterlines in a dental clinic from a Dentistry school of a Brazilian university. The design was an exploratory, descriptive study with quantitative and qualitative approach. Samples (n=4) were collected for analysis at different points: the portion closest to the water reservoir of the chair, and the portion closest to the triple syringe. After collection the samples were cultured in BHI medium in an oven for 24-48 h at 37 °C. For the quantitative analysis 1 ml of each sample was used for serial dilution up to the dilution value seven. The colonies were counted after pour plate and the results expressed in UFC/cm2. The qualitative analysis was initiated with the cultivation of Agar Blood, EMB-Levine and Cetrimide Agar for 24 h, and the identification of bacteria was performed by microscopic analyses. The resistance profile was verified by classical antibiogram. The internal surfaces of unit waterlines units exhibited a mean of 2.44 x 109 CFU / cm2. Bacillus subtilis and Pseudomonas aeruginosa were identified. The resistance profile of Pseudomonas aeruginosa indicated sensitivity to all tested antibiotics. A large number of microorganisms was quantified from biofilm accumulated in the dental units' waterlines. However, they were not resistant to classic antibiogram. Better management and application of decontamination protocols for waterlines need to be applied since opportunistic infections may be associated with Pseudomonas aeruginosa.


RESUMEN: La contaminación de líneas de agua en las unidades dentarias es una realidad, generando enfermedades individuales y colectivas. El objetivo de este estudio fue evaluar la prevalencia y resistencia de las bacterias en las zonas internas de las líneas de agua de la Facultad de Odontología de una universidad brasileña. El diseño del estudio fue exploratorio, descriptivo con enfoques cuantitativos y cualitativos. Las muestras para análisis (n=4) fueron selecionadas de distintos lugares: el punto más cercano al sistema de agua del sillón odontológico y el punto más cercano a la jeringa tríplice. Las muestras obtenidas fueron cultivadas en un médio BHI por 24-48 h, en un horno a 37 ºC. Para el análisis cuantitativo, se utilizó 1 ml de cada muestra para dilución hasta el valor siete. Las colonias fueran contadas y los resultados fueron expresados en UFC/cm2. El análisis cualitativo fue iniciado con el cultivo de Agar Sangre, EBM-Levine y Agar Cetrimide por 24 h y la identificación de la bacteria fue realizada por análisis microscópicos. El perfil de resistencia fue verificado por el antibiograma clásico. Las zonas internas de las unidades de líneas de agua mostraron un promédio de 2,44 x 109 UFC/cm2. Bacillus subtilis y Pseudomonas aeruginosa fueron encontrados. El perfil de resistencia de Pseudomonas aeruginosa indicó sensibilidad a todos los antibióticos testados. Un gran número de microorganismos fue cuantificado desde la biopelícula acumulada en las líneas de agua de unidades dentales. Sin embargo, no resistieron al antibiograma clásico. Se requiere una mejor gestión y aplicación de protocolos de decontaminación en las líneas de agua debido a que las infecciones oportunistas puedan estar asociadas a Pseudomonas aeruginosa.


Subject(s)
Humans , Water/adverse effects , Biofilms , Infection Control, Dental/methods , Water Microbiology , Brazil , Colony Count, Microbial , Equipment Contamination/prevention & control , Prospective Studies , Dental Equipment/microbiology , Mycobacterium/growth & development
15.
J. bras. pneumol ; 45(3): e20170351, 2019. tab
Article in English | LILACS | ID: biblio-1012549

ABSTRACT

ABSTRACT Objective: Home nebulizers are routinely used in the treatment of patients with cystic fibrosis (CF). This study aims to evaluate the contamination of nebulizers used for CF patients, that are chronically colonized by Pseudomonas aeruginosa, and the association of nebulizer contamination with cleaning, decontamination and drying practices. Methods: A cross-sectional, observational, multicenter study was conducted in seven CF reference centers in Brazil to obtain data from medical records, structured interviews with patients/caregivers were performed, and nebulizer's parts (interface and cup) were collected for microbiological culture. Results: overall, 77 CF patients were included. The frequency of nebulizer contamination was 71.6%. Candida spp. (52.9%), Stenotrophomonas maltophilia (11.9%), non-mucoid P. aeruginosa (4.8%), Staphylococcus aureus (4.8%) and Burkholderia cepacia complex (2.4%) were the most common isolated pathogens. The frequency of nebulizers' hygiene was 97.4%, and 70.3% of patients reported cleaning, disinfection and drying the nebulizers. The use of tap water in cleaning method and outdoor drying of the parts significantly increased (9.10 times) the chance of nebulizers' contamination. Conclusion: Despite the high frequency hygiene of the nebulizers reported, the cleaning and disinfection methods used were often inadequate. A significant proportion of nebulizers was contaminated with potentially pathogenic microorganisms for CF patients. These findings support the need to include patients/caregivers in educational programs and / or new strategies for delivering inhaled antibiotics.


RESUMO Objetivo: Nebulizadores caseiros são usados rotineiramente no tratamento de pacientes com fibrose cística (FC). Este estudo objetiva avaliar a contaminação de nebulizadores utilizados por pacientes de FC que estão cronicamente colonizados por Pseudomonas aeruginosa e a associação da contaminação do nebulizador com a higienização, esterilização e método de secagem. Métodos: Um estudo transversal, observacional, multicêntrico foi conduzido em sete centros de referência de FC no Brasil para obter dados de registros médicos; foram feitas entrevistas estruturadas com os pacientes/cuidadores e partes de nebulizadores (máscara e copo) foram coletados para cultura microbiológica. Resultados: No geral, 77 pacientes com FC foram incluídos. A frequência da contaminação do nebulizador foi de 71,6%. Candida spp. (52,9%), Stenotrophomonas maltophilia (11,9%), P. aeruginosa não mucoide (4,8%), Staphylococcus aureus (4,8%) e complexo Burkholderia cepacia (2.4%) foram os patógenos isolados mais comuns. A frequência de higienização dos nebulizadores foi de 97,4%, e 70,3% dos pacientes relata higienização, esterilização e secagem dos aparelhos. A lavagem com água da torneira e secagem das partes no tempo, em espaço aberto, aumentou significativamente (9 a 10 vezes) a chance de contaminação dos nebulizadores. Conclusões: Apesar dos relatos de frequente higienização dos nebulizadores, os métodos de limpeza e esterilização usados eram inadequados. Uma proporção significativa de nebulizadores foi contaminada com microrganismos potencialmente patogênicos para pacientes com FC. Estes resultados apoiam a necessidade de inclusão dos pacientes/cuidadores em programas educacionais e/ou novas estratégias para fornecimento de antibióticos inalatórios.


Subject(s)
Humans , Male , Female , Child , Adolescent , Adult , Young Adult , Pseudomonas aeruginosa/isolation & purification , Nebulizers and Vaporizers/microbiology , Equipment Contamination/statistics & numerical data , Cystic Fibrosis/therapy , Reference Values , Brazil , Colony Count, Microbial , Logistic Models , Decontamination/methods , Decontamination/statistics & numerical data , Disinfection/methods , Disinfection/statistics & numerical data , Equipment Contamination/prevention & control , Cross-Sectional Studies
16.
Rev. latinoam. enferm. (Online) ; 27: e3125, 2019. graf
Article in Portuguese | LILACS, BDENF | ID: biblio-1004251

ABSTRACT

Objetivos durante a punção venosa periférica, recomenda-se o uso de um garrote acima do local da punção para potencializar a distensão venosa. Dadas as suas características e o uso em ambientes clínicos, os garrotes podem representar uma fonte de disseminação de micro-organismos. Entretanto, os resultados de estudos científicos nessa área estão dispersos na literatura. Esta revisão de escopo tem como objetivo mapear as evidências disponíveis a respeito das práticas dos profissionais de saúde no que concerne ao uso do garrote durante a punção venosa periférica e à contaminação microbiológica associada. Método revisão de escopo de acordo com a metodologia do Instituto Joanna Briggs. Dois revisores independentes analisaram a relevância dos estudos, extraíram e sintetizaram dados. Resultados quinze estudos foram incluídos na revisão. Em geral, os garrotes foram reutilizados sem processos de descontaminação recorrentes. Verificou-se que os profissionais compartilham esses dispositivos entre si e os usaram continuamente por períodos entre duas semanas e sete anos e meio. Conclusão as práticas de enfermagem relacionadas ao uso do garrote durante a punção venosa periférica não são uniformes. A reutilização de garrotes pode colocar em risco a segurança do paciente se o reprocessamento (limpeza e desinfecção/esterilização) não for adequado, dado o tipo de material do garrote e a microbiota encontrada. Novos estudos são necessários para avaliar o impacto de vários tipos de práticas de reprocessamento na descontaminação de garrotes e na segurança do paciente.


Objectives during peripheral venipuncture, health professionals are recommended to use a tourniquet above the puncture site in order to potentiate venous distension. Given its characteristics and use in clinical settings, tourniquets may represent a source of microorganism dissemination. However, the results of scientific studies in this area are scattered in the literature. This scoping review aims to map the available evidence on health professionals' practices related with tourniquet use during peripheral venipuncture and associated microbiological contamination. Methods scoping review following the Joanna Briggs Institute methodology. Two independent reviewers analyzed the relevance of the studies, extracted and synthesized data. Results fifteen studies were included in the review. Overall, tourniquets were reused without being subject to recurring decontamination processes. It has been found that practitioners share these devices among themselves and use them successively for periods between two weeks and seven and half years. Conclusion nursing practices related to tourniquet use during peripheral venipuncture are not standard. Reuse of tourniquets may jeopardize the patient's safety if reprocessing (cleaning and disinfection/sterilization) is not adequate, given the type of tourniquet material and microbiota found. New studies are needed to assess the impact of various types of reprocessing practices on tourniquet decontamination and patient safety.


Objetivos durante la punción venosa periférica, se recomienda el uso de un garrote arriba del sitio de la punción para potenciar la distensión venosa. Dadas sus características y uso en ambientes clínicos, los garrotes pueden representar una fuente de diseminación de microorganismos. Sin embargo, los resultados de estudios científicos en esta área están dispersos en la literatura. Esta revisión de alcance tiene como objetivo mapear las evidencias disponibles acerca de las prácticas de los profesionales de salud en lo que concierne al uso del garrote durante la punción venosa periférica y la contaminación microbiológica asociada. Método revisión de alcance de acuerdo con la metodología del Instituto Joanna Briggs. Dos revisores independientes analizaron la relevancia de los estudios, extrajeron y sintetizaron datos. Resultados quince estudios se incluyeron en la revisión. En general, los garrotes fueron reutilizados sin procesos de descontaminación recurrentes. Se verificó que los profesionales comparten estos dispositivos entre sí y los utilizaron continuamente por períodos entre dos semanas y siete años y medio. Conclusión las prácticas de enfermería relacionadas al uso del garrote durante la punción venosa periférica no son uniformes. La reutilización de garrotes puede poner en riesgo la seguridad del paciente si el reprocesamiento (limpieza y desinfección/esterilización) no es adecuado, dado el tipo de material del garrote y la microbiota encontrada. Nuevos estudios son necesarios para evaluar el impacto de varios tipos de prácticas de reprocesamiento en la descontaminación de garrotes y en la seguridad del paciente.


Subject(s)
Humans , Professional Practice , Catheterization/methods , Central Venous Pressure/physiology , Disinfection/instrumentation , Equipment Contamination/prevention & control , Portugal , Health Personnel , Phlebotomy/methods
17.
Hig. aliment ; 32(286/287): 87-91, dez. 2018. ilus
Article in Portuguese | LILACS, VETINDEX | ID: biblio-1481876

ABSTRACT

Esta pesquisa teve como objetivos verificar a eficiência dos processos de higienização de tanques de granelização de três propriedades rurais (A, B e C) no município de Rio Pomba - Minas Gerais e implantar procedimentos padrão de higiene operacional (PPHO) para higienização dos tanques. Para verificação das condições de higienização, foi coletada em triplicada amostras de três locais dos tanques pela da técnica de swab, delimitando uma área de 50 cm² e analisado o grau de contaminação por mesófilos aeróbios e coliformes totais e termotolerantes. Após análise, foi implantado PPHO para higiene dos tanques e mãos dos responsáveis pela higienização dos tanques nas propriedades. Após, fez-se novamente análise do tanque para verificar a eficiência do PPHO implantado. Verificou-se que após a implantação do PPHO, o tanque do produtor A obteve uma redução de até quatro ciclos logarítmicos para os grupos de micro-organismos mesofilos aeróbios e cerca de 3 e 2 ciclos para coliformes totais e termotolerantes, respectivamente. Os tanques dos produtores B e C apresentaram baixas contagens de mesófilos e coliformes antes e após a implantação do PPHO. Conclui-se que a implantação do PPHO foi satisfatória, contribuindo para uma menor contagem de micro-organismos aderidos ao tanque do produtor A.


This research had as objectives to verify the efficiency of the sanitation processes of expansion tanks of three rural properties (A, B and C) in the municipality of Rio Pomba - Minas Gerais and to implement standard procedures of operational hygiene (PPHO) to sanitize tanks. ln order to verify the hygienization conditions, samples of three tanks locations were collected in triplicate using the swab technique, delimiting an area of 50 cm² and analyzing the degree of contamination by total and thermotolerant aerobic and total coliforms. After analysis, PPHO was implanted for hygiene of the tanks and hands of those responsible for the hygiene of the tanks in the properties. Afterwards, the tank was again analyzed to verify the efficiency of the implanted PPHO. lt was verified that after the implantation of the PPHO, the tank of producer A obtained a reduction of up to four logarithmic cycles for the groups of aerobic mesophilic microorganisms and about 3 and 2 cycles for total and thermotolerant coliforms, respectively. The tanks of producers B and C showed low counts of mesophiles and coliforms before and after PPHO implantation. lt is concluded that the implantation of the PPHO was satisfactory, contributing to a lower count of microorganisms adhered to the tank of the producer A.


Subject(s)
Equipment Contamination/prevention & control , Food Hygiene/standards , Storage Tanks/analysis , Colony Count, Microbial , Milk
18.
Rev. enferm. UERJ ; 26: e26388, jan.-dez. 2018. tab
Article in Portuguese | LILACS, BDENF | ID: biblio-948549

ABSTRACT

Objetivo: determinar o perfil microbiológico de bactérias isoladas e identificadas nos leitos e bombas infusoras na unidade de terapia intensiva de um hospital universitário do Estado do Rio de Janeiro. Método: foram coletadas nove amostras de grades das camas dos pacientes e oito de teclados de bomba infusora de uma unidade de terapia intensiva, em outubro de 2014, delimitando-se uma área de 100cm² como parâmetro para ambas as coletas. As amostras foram coletadas através de swabs estéreis que foram umedecidos e transportados em Carry & Blair. Os microrganismos foram isolados, classificados e depois testados em relação à resistência antimicrobiana. Resultados: o gênero Staphylococcus coagulase negativa foi o mais prevalente. Os testes de suscetibilidade a antimicrobianos apontaram alguns destes Staphylococci como multirresistentes. Conclusão: chama-se atenção para a necessidade de ampliação do debate multiprofissional sobre questões de segurança hospitalar, apresentando a educação permanente como um possível caminho de sucesso no controle das infecções.


Objective: to determine the microbiological profile of bacteria isolated and identified from beds and infusion pumps in the intensive care unit of a university hospital in Rio de Janeiro state. Method: nine samples were collected from patients' bed side rails and eight from infusion pump keypads in an intensive care unit in October 2014. An area of 100cm² was delimited as the sampling parameter. Samples were collected using sterile swabs, which were wetted and transported with Cary-Blair. The microorganisms were isolated, classified, and then tested for antimicrobial resistance. Results: coagulase-negative Staphylococcus was the most prevalent type. Antimicrobial susceptibility testing indicated some of these Staphylococci were multi-drug resistant. Conclusion: multi-professional discussion of hospital safety issues must be expanded, and continuing professional development emerges as one possible pathway to success in nosocomial infection control.


Objetivo: determinar el perfil microbiológico de bacterias aisladas e identificadas en las camas y las bombas de infusión en la unidad de terapia intensiva de un hospital universitario de Rio de Janeiro. Método: se recolectaron nueve muestras de rejas de camas de pacientes y ocho de paneles de las bombas de infusión de una unidad de terapia intensiva, en octubre de 2014, delimitandose un área de 100 cm2 como parámetro para ambas recolecciones. Se recolectaron las muestras a través de swabs estériles que fueron humedecidos y transportados en Carry y Blair. Los microorganismos fueron aislados, clasificados y después probados repecto a la resistencia antimicrobiana. Resultados: el género Staphylococcus coagulasa negativo fue el más prevalente. Las pruebas de susceptibilidad a antimicrobianos mostraron algunos Staphylococci como resistentes a múltiples fármacos. Conclusión: se señala la necesidad de ampliación del debate entre los profesionales de la salud, sobre cuestiones de seguridad hospitalaria, presentando la educación permanente como un posible camino de éxito en el control de las infecciones.


Subject(s)
Bacteria/isolation & purification , Beds/microbiology , Infusion Pumps/microbiology , Cross Infection/prevention & control , Equipment Contamination/prevention & control , Intensive Care Units , Brazil , Cross-Sectional Studies , Infection Control , Critical Care Nursing
19.
Arq. bras. oftalmol ; 81(5): 371-375, Sept.-Oct. 2018. tab, graf
Article in English | LILACS | ID: biblio-950483

ABSTRACT

ABSTRACT Purpose: The aim of this study was to analyze the bacterial and fungal microbiota found in contact lens cases among two groups of patients to correlate the data on the habits of contact lens users and to evaluate whether there is a difference in the culture results between users of ridged and nonridged contact lens cases. Methods: Two groups (35 patients per group) were included, consisting of hospital workers and those who had not visited a hospital in the past 30 days, and a questionnaire regarding epidemiological data and habits related to contact lens and lens case use was administered. In addition, 140 samples collected from the right and left compartments of each lens case by swabbing the bottom of the wells were tested using bacterioscopy as well as fungal and bacterial cultures via computerized identification of the species. Results: No fungal growth was identified in any of the 70 contact lens cases; however, bacteria were found in 39 cases, and there was no statistical difference between the groups. Most bacteria (>85%) were gram-negative bacilli. Contamination inone compartment of the contact lens case elevated the risk of contamination of the other side (>80%). Moreover, contamination was statistically higher in the ridged cases than in nonridged cases (p=0.0149). Conclusion: The types of bacteria contaminating the cases are generally not seen in eye diseases associated with contact lens use, suggesting that other decisive variables are involved in eye infection from a contaminated lens or case. Fungal contamination of contact lens cases appears to be an exception. Ridged cases are commonly used by contact lens wearers and present a potential risk to eye health. In addition, the results of bacterial tests between hospital workers and those who did not visit a hospital were not significantly different.


RESUMO Objetivo: O objetivo deste trabalho foi analisar a microbiota bacteriana e fúngica encontrada em estojos de lentes de contato em dois grupos, correlacionar os dados sobre os hábitos de uso de lentes de contato e avaliar se há diferença na positividade das culturas entre os usuários estojos de lentes de contato com ranhuras e sem ranhuras. Métodos: Dois grupos foram formados, trabalhadores do hospital e pessoas que não visitaram o hospital (35 indivíduos por grupo), e um questionário foi aplicado sobre dados epidemiológicos e hábitos relacionados ao uso de lentes de contato e estojos de lentes. Além disso, 140 amostras, coletadas do compartimento direito e esquerdo de cada estojo de lente, esfregando o fundo dos mesmos, foram testadas por bacterioscopia e por culturas de fungos e bactérias, com identificação computadorizada da espécie. Resultados: Não houve crescimento fúngico em nenhum dos 70 estojos de lentes de contato, porém bactérias foram encontradas em 39; não houve diferença estatística entre os grupos. A maioria das bactérias (>85%) eram bacilos gram-negativos. Quando um compartimento estava contaminado, o risco de contaminação do outro compartimento era elevado (>80%). A contaminação foi estatisticamente maior nos estojos com ranhuras (p=0,0149). Conclusão: A contaminação dos estojos parece ocorrer por bactérias que, em geral, não são encontradas em doenças oculares associadas ao uso de lentes de contato, sugerindo que existem outras variáveis decisivas nas infecções oculares de uma lente ou estojo contaminado. Contaminação de estojos de lentes de contato com fungos parece ser uma exceção. O uso de estojos com ranhuras é uma prática comum e apresenta um risco potencial à saúde ocular. Não foram encontradas diferenças significativas nos resultados dos testes bacterianos entre trabalhadores hospitalares e pessoas que não visitaram o hospital.


Subject(s)
Humans , Equipment Contamination/statistics & numerical data , Contact Lenses/microbiology , Gram-Negative Bacteria/isolation & purification , Equipment Contamination/prevention & control , Surveys and Questionnaires , Fungi/isolation & purification , Gram-Negative Bacteria/classification , Gram-Positive Bacteria/isolation & purification , Gram-Positive Bacteria/classification
20.
Rev. chil. infectol ; 35(1): 88-90, 2018. graf
Article in Spanish | LILACS | ID: biblio-1042644

ABSTRACT

Resumen Introducción La atención odontológica se ha transformado en un desafío para los programas de prevención y control de infecciones asociadas a la atención de salud (IAAS), dado que el ambiente, entre otros factores, juega un rol importante en la cadena de transmisión. Método Se realizó un programa de intervención en el Servicio de Dental del Hospital Militar de Santiago, entre los años 2014-2015, que contempló tres etapas: etapa diagnóstica, de intervención y de evaluación. Objetivo Mejorar la seguridad de las superficies críticas involucradas en la atención dental. Resultados Durante la etapa diagnóstica se constató que el proceso de limpieza y desinfección era deficiente. La superficie crítica más contaminada fue la unidad porta-instrumental, luego el área limpia y la manilla de la lámpara. Las superficies que redujeron significativamente su contaminación, posterior a la intervención, fueron el área limpia y la unidad porta-instrumental. Conclusiones La capacitación en relación a los procesos de limpieza y desinfección de superficies y del equipamiento dental es una de las estrategias costo-eficientes en la prevención de las IAAS, sencilla y fácil de aplicar.


Introduction Dental care has become a challenge for healthcare associated infection prevention programs, since the environment, within other factors, plays an important role in the transmission chain. Materials and Methods An intervention program was designed for the Dental Unit of Hospital Militar de Santiago, between years 2014 and 2015. The program contemplated 3 stages: diagnostic, intervention and evaluation stage. Objective To improve the safety of critical surfaces involved in dental healthcare. Results During the diagnostic stage, the cleaning and disinfection process was found to be deficient. The most contaminated critical surface was the instrument holder unit, then the clean area and lamp handle. The surfaces that significantly reduced their contamination, after the intervention, were the clean area and the instrument carrier unit. Conclusion Training in the processes of cleaning and disinfecting surfaces and dental equipment is one of the cost-effective strategies in preventing healthcare-associated infections (HCAI), with simple and easy-to-apply methods.


Subject(s)
Disinfection/methods , Cross Infection/prevention & control , Equipment Contamination/prevention & control , Dental Equipment/microbiology , Dental Health Services , Surface Properties , Program Evaluation , Adenosine Triphosphate/analysis , Disinfection/standards , Reproducibility of Results , Infection Control/methods , Infection Control/standards , Luminescent Measurements